Double controlled constant temperature Incubator shaker price for laboratory
Horizontal superimposed constant temperature (model 2016 series):
The superimposed constant temperature shaker is widely used in bacterial culture, fermentation, hybridization and biochemical reactions, fermentation, cell tissue research, etc., which have high requirements on temperature, oscillation frequency and amplitude. Has a broad and important role in research applications in medicine, biology, molecular science, pharmaceuticals, food, and environmental protection.
1.Two oscillation modes, cyclotron oscillation or reciprocating oscillation mode.
2.The three stacks are stacked together, but still occupy only one shaker area.
3.The humanized down-opening door design is in line with ergonomics.
4.The slide platform has a large bearing area and a smooth sliding.
5.The rocker is made of electroplated aluminum to avoid rust or corrosion.
6.The large internal space can accommodate up to 2L of culture flasks.
7.Available in both temperature and low temperature ranges.
8.The transparent viewing window and built-in lighting design make it easy to view samples at any time.
9.Simultaneous observation of temperature, oscillation speed, time
10.Sound and light report alarm environment scanning processing chip, with more powerful data processing functions.
11.Eight sections of self-programming, each program can set different speed and time to realize the programming operation of speed and appointment time.
12.Independent overspeed sound/light alarm, independent leakage, and over-current protection devices do not affect other equipment.
13.The original single-axis drive mechanism in China is quiet and durable.
14.The oscillation frequency can be extended over a wide range to 50-300 rpm.
15.Unique high-precision frequency control system with frequency accuracy of ±1rpm.
16.Safety and fluorine-free refrigeration system in line with international environmental protection requirements
17.Run the parameter memory function to avoid cumbersome operations.
18.The line that controls the acceleration ensures that the shaker is slowly started and smoothly accelerated to ensure the safety of the experimental samples.
19.Over-temperature sound and light alarm function, motor overheating, temperature out of control, abnormal over-temperature instrument automatically cut off their respective power supply.
20.The unique slow start line prevents sudden starts and splashes, ensuring safe reagents.
21.AC induction long life motor design, wide speed regulation, constant torque, constant speed, no carbon brush, maintenance free.
22.With power-off recovery function, after the external power supply suddenly loses power and calls again, the device can automatically resume operation according to the original setting program.
23.Unique motor overheating, temperature out of control automatic power off protection device.
24.The electrostatic color spray box is beautiful and rustproof, and has an aesthetic design concept.
25.Stainless steel mirror cavity, no rust and rust.
26.Made of high quality, high strength cold rolled steel, medium, channel, angle and cast iron.
2. Security
1.Leakage current and overcurrent protection systems ensure operator safety.
2.Ultra-temperature, over-speed sound and light alarm emergency control system to ensure sample safety.
3. Application range
1.Cell culture
2.Solubility test
3.Extraction experiment
4.Diagnostic test
5.Mixing samples
6.Bacterial suspension preparation
7.Dyeing and bleaching
8.Elution process
9.Hybrid experiment
Model |
LJS-2016 |
LJS-F2016 |
LJS-D2016 |
LJS-2016R |
LJS-F2016R |
LJS-D2016R |
Temperature control method |
Single temperature control |
Full temperature control |
control method |
P.I.D (microcomputer environment scanning micro processing chip) |
Display method |
LED (large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Rotate |
Reciprocating |
Rotate |
Rotate |
Reciprocating |
Rotate |
Drive mode |
Single-axis balancing device (Chinese patent ultra-low mute) |
temperature range |
+5ºC-60ºC |
4ºC-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
security function |
Upper and lower limit over-temperature sound and light alarm; upper and lower limit overspeed alarm, independent over-temperature protector; open door stop protection; leakage or over-current protection device |
Accessory function |
Speed storage, one-button factory reset, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, pacing, eight-segment curve programming |
Rotation frequency |
30-300rpm |
Acceleration |
Slow start |
Rotation accuracy |
±1rpm |
Array amplitude |
25mm |
25mm |
50mm |
25mm |
25mm |
50mm |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
Heater |
800W |
Timing range |
0.999.59 hours / sustainable |
Rocker size |
920*540(mm) |
Maximum capacity |
250ml*60/500*40/1000*24/2000*15 |
Number of rocking plates |
one |
net weight |
180kg/set |
2000kg/set |
Inner cavity size |
1120*595*398H(mm) |
Dimensions |
1410*785*640H (single) Without foot 90mm |
1410*785*1280H (Two stacks) Without foot 90mm |
1410*785*1920H (Triple stack) Without foot 90mm/ Padded high stool |
Opening method |
The following two layers: drop-down The third layer: upturn |
annex |
UV lamp, lighting |
power |
980W |
1200W |
Motor |
120W inverter motor |
power supply |
AC 200-240V 50-60HZ |
Inner cavity material |
All 304 high quality imported stainless steel mirror panel |
Box material |
High quality and high strength channel steel, angle steel, cold rolled steel plate |
Vertical superimposed constant temperature shaker(model 2013 series):
The constant temperature shaker has a stainless-steel universal clamp, digital display temperature control, stepless speed regulation and good thermal cycle function. It is a multi-purpose biochemical device, which is a plant, biology, microbiology, genetics, virus, environmental protection, medicine and other scientific research. education and production departments for precision culture preparation of indispensable laboratory equipment
1.Feature
- The patented technology of the original single-axis drive mechanism in China is quiet and durable
- The sound and light alarm environment scanning processing chip has more powerful data processing functions.
- Eight sections of self-programming, each program can set different speed and time to realize the programming operation of speed and appointment time.
- Independent overspeed sound/light alarm, independent leakage, over-current protection does not affect other equipment.
- The oscillation frequency can be extended to a wide range of 30-300 rpm.
- Unique high-precision frequency control system with frequency accuracy of ±1rpm.
- A safe, fluorine-free refrigeration system that meets international environmental requirements.
- Run the parameter memory function to avoid cumbersome operations.
- The line that controls the acceleration ensures that the shaker starts slowly and accelerates smoothly to ensure the safety of the experimental samples.
- Over-temperature sound and light alarm function, the motor overheats, the temperature is out of control, the abnormal over-temperature instrument automatically cuts off the respective power supply.
- The unique slow start line prevents sudden starts and splashes, ensuring safe reagents.
- High quality variable frequency motor, wide speed regulation, constant torque, no carbon brush, maintenance free.
- With power-off recovery function, after the external power supply suddenly loses power and calls again, the device can automatically resume operation according to the original setting program.
- The electrostatic color spray box is beautiful and rustproof.
- Stainless steel mirror cavity, high-quality stainless-steel bottle holder.
- High quality and high strength cold rolled steel, medium plate, channel steel, angle steel, cast iron.
- Large screen tempered glass window.
- Double oscillation mode, cyclotron oscillation / reciprocating oscillation switchable.
- The shaker can be placed on the bench or under the stage, and the two shakers can be stacked and landed.
- The height-adjustable partition allows for easy storage of more samples and can be used for stationary culture.
- The front opening design makes the shaker more flexible than turning the door shaker up.
- The large internal space allows for a maximum capacity of 5L culture bottles.
- Available in both temperature and low temperature ranges.
- The transparent viewing window and built-in lighting design make it easy to view samples at any time.
- Simultaneous observation of temperature, oscillation speed, time
2.Security
- Leakage current and overcurrent protection systems ensure operator safety.
- Over-temperature, over-speed sound and light alarm emergency control system to ensure sample safety
3.Application range
- Bacterial suspension preparation
- Solubility test
- Extraction experiment
- Mixing samples
- Dyeing and bleaching
- Hybrid experiment
- Diagnostic test
- Elution process
- Protein
- Plasmid purification
4.Specification
Model |
LJS-2013 |
LJS-2013R |
LJS-2013-2(Double layer) |
LJS-2013-2R (Double layer) |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
LCD (Large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Reciprocating/rotating switching |
Rotary oscillation |
Drive mode |
Single-axis balancing device (Chinese patent) |
temperature range |
+5ºC-60ºC |
4ºC-60ºC |
+5ºC-60ºC |
4ºC-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
Rotation frequency |
50-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
φ25mm |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
|
200W |
Heater |
800W |
Timing range |
0-999.59h/ Sustainable |
Rocker size |
456*450 (mm) bottle splint. 450*400 (mm) culture shelf |
Maximum configuration |
5000ml*4 or 1000ml*9 or 500ml*16 or 250ml*20 |
500ml*32 or 250ml*40 or 100ml*60 or 50ml*60 |
Number of rocking plates |
One piece of plywood, one piece of static culture shelf (one layer of oscillation) |
Two blocks (two layers of oscillation) |
Gross weight |
120kg/set |
150kg/set |
120kg/set |
150kg/set |
Inner cavity size |
560*500*555H(mm) |
Dimensions |
650*820*810H(Single)/ Without foot 90mm |
650*820*1620H (Two stacks) Without foot 90mm |
annex |
Lighting, ultraviolet light |
power |
600w |
830w |
600w |
830w |
Motor |
60W inverter motor |
power supply |
AC 200-240V 50-60HZ |
Inner cavity material |
All 304 high quality imported stainless steel mirror panel |
Box material |
High quality and high strength channel steel, angle steel, cold rolled steel plate |
Double row double controlled constant temperature shaker(model LK-2018 series):
The double-row dual-controlled shaker has a 7-inch true color touch-type touch screen and a microcomputer environment scanning processing chip, which uses a high-speed cycle to rotate the product, and has a speed storage, call recovery, parameter memory, temperature speed correction, and clock display. Light function.
1.Feature
- Double-row dual control, international originality, patented technology.
- Large screen 7-inch true color touch screen, icon display, easy to operate.
- Double-layer rocking plate, large internal space can be placed up to 2000ml Erlenmeyer flask.
- Easy to pick and place, no need to rub or squat.
- There is no need to pull the rocking plate, no need to fix the rocking plate, and it is convenient to take and place the container.
- The same area, the same amount of bottling, cost-effective.
- Adjust the foot and roller up and down. Easy to transport and install.
- Luxury machine shape, open the door to the high-end atmosphere.
- There are two temperature ranges, constant temperature and low temperature.
- The transparent viewing window and built-in lighting design make it easy to view samples at any time.
- Observe the temperature, oscillation speed, and time at the same time.
- Sound and light report alarm environment scanning processing chip, with more powerful data processing function
- Eight sections of self-programming, each program can set different speed and time to realize the programming operation of speed and appointment time.
- Independent overspeed sound/light alarm, independent leakage, and over-current protection devices do not affect other equipment.
- The original single-axis drive mechanism in China is quiet and durable.
- The oscillation frequency can be extended over a wide range to 50-300 rpm.
- Unique high-precision frequency control system with frequency accuracy of ±1rpm.
- Safety and fluorine-free refrigeration system in line with international environmental protection requirements
- Run the parameter memory function to avoid cumbersome operations.
- The line that controls the acceleration ensures that the shaker is slowly started and smoothly accelerated to ensure the safety of the experimental samples.
- Over-temperature sound and light alarm function, motor overheating, temperature out of control, abnormal over-temperature instrument automatically cut off their respective power supply.
- The unique slow start line prevents sudden starts and splashes, ensuring safe reagents.
- AC induction long life motor design, wide speed regulation, constant torque, constant speed, no carbon brush, maintenance free.
- With power-off recovery function, after the external power supply suddenly loses power and calls again, the device can automatically resume operation according to the original setting program.
- Unique motor overheating, temperature out of control automatic power off protection device.
- The electrostatic color spray box is beautiful and rustproof, and has an aesthetic design concept.
- Stainless steel mirror cavity, no rust and rust.
- Made of high quality, high strength cold rolled steel, medium, channel, angle and cast iron.
- Practical and aesthetic design concept, streamlined luxury machine shape, large screen tempered glass window
2.Security
- Leakage current and overcurrent protection systems ensure operator safety.
- Over-temperature, over-speed sound and light alarm emergency control system to ensure sample safety
3.Application range
- Cell culture
- Solubility test
- Extraction experiment
- Diagnostic test
- Mixing samples
- Bacterial suspension preparation
- Dyeing and bleaching
- Elution process
- Hybrid experiment
4.Specification
Model |
LK-2018 |
LK-2018R |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
7-inch true color touch screen |
Cyclic mode |
High speed circulation |
Oscillation mode |
Rotary oscillation |
Drive mode |
Single-axis balancing device (Chinese patent, ultra-low mute) |
studio |
2 |
temperature range |
+5ºC-60ºC |
4ºC-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
Print function |
Embedded built-in micro printer, USD interface |
Rotation frequency |
20-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
φ25mm |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
400W |
Heater |
1600W |
Timing range |
0-999.59h/ Sustainable |
Rocker size |
498*460(mm) |
Number of rocking plates |
Four blocks |
Maximum capacity |
250ml*80or500ml*64or1000ml*36or 2000ml*24 |
net weight |
480kg/set |
Volume |
260L*2 |
Inner cavity size |
607*506*875H |
Dimensions |
1350*645*1620mm (with adjustable foot/roller) |
Opening method |
Opening the door |
annex |
Lighting, ultraviolet light |
power |
1920w |
2240w |
power supply |
AC 200-240V 50-60HZ |
Inner cavity material |
All 304 high quality imported stainless steel mirror panel |
Box material |
High quality and high strength channel steel, angle steel, cold rolled steel plate |
We also have other shaker as follows: