Customization: | Available |
---|---|
Type: | Feeler Gauge |
Material: | Aluminum Alloy |
Still deciding? Get samples of US$ 810/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Feature:
1. Economical full digital thickness gauge
All-digital thickness gauge needs to convert analog ultrasonic signals into digital signals, and then process the digital signals to obtain high-performance thickness measurement capability. The A-scan snapshot function, zero-crossing measurement technology and high resolution of LM-4 series are all based on all-digital technology.
2. The innovative A-scan snapshot function
LM-4 is the first product in the same file to provide A scan waveform display function. Acoustic non-ultrasonic wave is no longer an abstract concept that cannot be seen or touched. Users can directly see the ultrasonic signal waveform on the screen, which is used to verify whether the thickness reading is correct, analyze the cause of the problem, and help users find a solution to the problem.
3. Adopt breakthrough zero-crossing measurement technology
Based on all-digital technology and zero-crossing measurement technology, the thickness measurement value is not affected by echo intensity, material attenuation coefficient, gain and gate height, and has high measurement stability and reliability.
4. The function of penetrating the coating
(1) Zero-free calibration;
(2) high stability, the measured value is not affected by probe pressure, coupling layer thickness and dust stains on the surface of the workpiece;
(3) Zero drift.
5. More practical functions
(1) Gain: adjustable for high, medium and low gears;
(2) Alarm mode: dynamically change thickness reading color during alarm;
(3) Difference/Reduction Rate: The difference mode shows the difference between the measured thickness and the preset thickness. The reduction rate is the percentage of thickness reduction calculated and displayed after the material is thinned. The typical application is to measure the metal material thinned due to bending.
(4) Maximum/Minimum Capture: The current thickness value, minimum thickness value and maximum thickness value are simultaneously displayed on the screen.
Specification:
Model |
LM-4D |
|||
Measuring range |
0.65-508 mm (0.025 - 20.00 inches) depends on the probe used, the material to be tested, and the surface condition. |
|||
Penetration coating function |
YES |
|||
Working principle |
Ultrasonic Pulse Echo Method Using Double Crystal Probe |
|||
Lower limit of pipe measurement (steel) |
φ 20 mm * 3.0 mm (PT08 probe); φ 15 mm * 2.0 mm (small diameter tube probe) |
|||
Measurement resolution |
0.01 or 0.1mm (0.001 or 0.01in) |
|||
Unit |
Millimeters or inches |
|||
Display |
2.4QVGA (320×240) color OLED screen with contrast ratio of 10000:1 |
|||
Repeatability |
±0.05mm |
|||
Probe calibration |
One-point calibration, two-point calibration |
|||
Measurement error |
0.05 mm (less than 10 mm) (0.5% h+0.01) (more than 10 mm) Note: h is the thickness of the measured object |
|||
The measurement update rate |
4HZ, 8HZ and 16HZ per second are optional. |
|||
The sound speed range of the material |
500-9999m/s,0.0179-0.3937in/us |
|||
Storage function |
Store100,000 thickness values |
|||
Alarm function |
The maximum/minimum alarm, alarm dynamically change the thickness reading color |
|||
Gain |
High, Medium and Low Gear Adjustable |
|||
Display mode |
Thickness value mode, minimum/maximum capture mode, difference/reduction rate mode |
|||
V path correction |
Automatic A-range correction to compensate nonlinearity of bimorph probe |
|||
Language |
Chinese, English, Japanese, German and French are available |
|||
Power supply |
two AA batteries |
|||
Operating time |
Two AA batteries for more than 35 hours |
|||
Automatically shut down |
Optional 5, 10, 20 minutes after no operation automatically shut down, or only manually shut down |
|||
Working temperature |
-10ºC ~+50ºC, with special requirements up to -20ºC |
|||
Size |
153*76*37mm |
|||
Weight |
280g (including battery) |
|||
Standard configuration |
Thickness gauge host, standard probe, instrument box, two alkaline batteries, coupling agent, operation manual, certificate of approval and packing list |
|||
Optional accessories |
Rubber jacket; A variety of selectable probes; Step test block for calibration; Coupling agent and high temperature coupling agent |
Configuration list |
|
Mainframe |
1 |
Coupling agent |
1 |
Probe |
1 |
Battery |
2 |
Packing document |
1 |
Instrument seal box |
1 |
Data line |
1(only LM-4DL) |
Communication software |
1(only LM-4DL) |
Note: If send it by air, not including batteries, it's an empty bottle for Coupling agent. |