• Laboao Large Anti-Explosion Heating Chilling Temperature Controller
  • Laboao Large Anti-Explosion Heating Chilling Temperature Controller
  • Laboao Large Anti-Explosion Heating Chilling Temperature Controller

Laboao Large Anti-Explosion Heating Chilling Temperature Controller

After-sales Service: Remote Online Guidance
Warranty: 12months
Application: Industry, School, Hospital, Lab, Heater Chiller Circulator
Customized: Customized
Certification: CE, ISO, Heater Chiller Circulator
Structure: Portable
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other, Group Corporation
  • Overview
  • Product Description
  • Product Parameters
  • Features
Overview

Basic Info.

Model NO.
LGD
Material
Corrosion Resistance
Type
Heater Chiller Circulator
Explosion Proof Level
Optoinal
Explosion Proof Parts
Control Box; Explosion-Proof Pump; Explosion-Proof
Cooling Agent
R22
Voltage
Customized
Heating Power
Customized
Operating Temperature Range
-20 ºC to +200ºC
Ambient Temperature
5-40degree Centigrade
Filling Amount of Bath Liquid
300L
Circulating Pump Power
250W
Maximum Flow
20-40L/Min
Maximum Pressure
≤0.4MPa
Head of Delivery
4-6m
Medium
Water or Oil
Display Screen
LCD Display, Key Operation
Function
Heater Chiller
Transport Package
Standard Polywood Case
Specification
580× 460× 805mm
Trademark
Laboao
Origin
China
Production Capacity
1000sets/Month

Product Description


Laboao Explosion proof heater chiller circulator 
Product Description

This product has both cooling and heating functions. It consists of refrigeration unit, heating unit, circulation system and control system.

The refrigeration part is mechanically refrigerated by a fully enclosed compressor, composed of a plate heat exchanger, an expansion valve, a pressure protector, etc. to meet the cooling requirements; the heating part uses an electric heating tube to heat the circulating liquid. And through the built-in circulating pump and external circulating pipeline, the refrigerant or heating medium is transported to the interlayer of the supporting equipment, and the material in the reactor is indirectly cooled and heated.
During external circulation, the upper outlet pipeline of the product is connected to the lower inlet pipeline of the kettle body, and the circulating liquid returns to the lower return port of the product from the upper circulation port through the pipeline to form a complete circulation space.
Laboao Large Anti-Explosion Heating Chilling Temperature ControllerLaboao Large Anti-Explosion Heating Chilling Temperature Controller

This product has both cooling and heating functions. It consists of refrigeration unit, heating unit, circulation system and control system.
The refrigeration part is mechanically refrigerated by a fully enclosed compressor, composed of a plate heat exchanger, an expansion valve, a pressure protector, etc. to meet the cooling requirements; the heating part uses an electric heating tube to heat the circulating liquid. And through the built-in circulating pump and external circulating pipeline, the refrigerant or heating medium is transported to the interlayer of the supporting equipment, and the material in the reactor is indirectly cooled and heated.
During external circulation, the upper outlet pipeline of the product is connected to the lower inlet pipeline of the kettle body, and the circulating liquid returns to the lower return port of the product from the upper circulation port through the pipeline to form a complete circulation space.



 
Product Parameters
 

Model

LGD-300/40EX

LGD-300/80EX

Matched reactor

300L

300L

Tank Volume(L)

80

80

Heating volume(L)

50

50

Heating tank size(mm)

¢550*550

¢550*550

Oil tank size(mm)

800*800*800

800*800*800

Working temperature range(ºC)

-40ºC to +200ºC

-80ºC to 200ºC

Ambient temperature(ºC)

≤25

≤25

Lowest temperature (No load)

-40ºC

-82ºC

Power

380V±10% 50HZ

380V±10% 50HZ

Heating power(W)

18000

24000

Temperature accuracy(ºC)

±0.1

±0.1

Sensor

PT100

PT100

Medium quality degree

500C.S.T

500C.S.T

Circulating pump power(w)

750

750

Lift head(m)

22

22

Flow(L/min)

80

80

The compressor   adopts explosion-proof treatment (explosion-proof control box, explosion-proof   circulating pump, explosion-proof fan, explosion-proof tube) explosion-proof   grade ExdIIBT4

 
Features

1. The temperature accuracy is generally ±1°C, and an external sensor can be connected (the temperature difference accuracy is generally ±0.5°C).
2. The maximum temperature limit to prevent the equipment from losing control [If the maximum temperature of the equipment is exceeded, the equipment will automatically power off.
3. Has power supply protection.
4. Compressor overheating protection, the compressor will stop working when the compressor withstand limit is reached.
5. Water cooling has water flow and low water pressure protection.
6. All compressors are imported compressors (France, Denmark)

Laboao Large Anti-Explosion Heating Chilling Temperature ControllerLaboao Large Anti-Explosion Heating Chilling Temperature ControllerLaboao Large Anti-Explosion Heating Chilling Temperature Controller

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now