Laboao Medical Cryogenic Ultra Low Temperature Deep Freezer
The Cascade System's microprocessor control system with 3 separate interior doors that can be opened independently. Minimize frost accumulation in the room.The unique door seal design minimizes the temperature loss when the door is opened. The stainless steel internal handle ensures that the door can be easily opened even in the case of frost. High quality door gasket 5 gasket, 4 sealing ring for door, 1 inner door seal to provide maximum protection against heat intrusion. The sample port on the back makes temperature monitoring convenient.
Feature
- The inner wall is made of high quality 304 stainless steel plate, which is durable and safe.
- Accurately keep the internal temperature of the box accurate and stable, the temperature inside the box is adjustable from -40ºC to -86ºC
- Fast cooling speed, low power consumption and large cooling capacity
- Standard test hole, USB interface and remote alarm interface
- VIPIIPLUS second generation vacuum insulation board technology, the refrigerator has good insulation performance, designed for entering the elevator
- Product structure optimized for biological sample libraries, providing storage space of up to 40,000 samples
- When power is restored, the simultaneous start of all equipment will cause a large impact on the power grid, which may cause the circuit breaker to trip; the specially designed equipment delay start function for this case may make the equipment
- The inner door is detachable for easy defrosting and cleaning
- New door handle, additional padlock; test hole design; adjustable stainless steel shelf; detachable inner door for customer cleaning and defrosting
- According to the user's needs, the space can be adjusted according to the specifications of the stored items.
- Malfunction alarms including high and low temperature, power failure, sensor error, clean-filter, and extremely high ambient,abnormal voltage, thermostat failure, low battery, condenser clean, door ajar
- Capable of producing two types of alarm outputs, audible buzzer and visible flashing light.
- Door open feature standard and USB port for temperature date downloading standard on upright models.
- Suitable for 10ºC to 32ºCambient temperature
- Unique insulated inner door design for four separate storage compartments to minimize frost buildup inside the chamber.
- Adjustable storage shelf height
Specification
|
Model |
LDF-86V58 |
LDF-86V188E |
LDF-86V340E |
LDF-86V408E |
LDF-86V588E |
LDF-86V728E |
LDF-86V838E |
Specifications |
Shelf/drawer QTY |
Stainless steel shelf/1 |
Stainless steel shelf/2 |
Stainless steel shelf/3 |
Stainless steel shelf/3 |
Stainless steel shelf/3 |
Stainless steel shelf/3 |
Stainless steel shelf/3 |
Cooling |
Direct cooling |
Direct cooling |
Direct cooling |
Direct cooling |
Direct cooling |
Direct cooling |
Direct cooling |
Defrost |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Refrigerant |
R4001 |
R4001 |
R4001 |
R4001 |
R4001 |
R4001 |
R4001 |
Power Consumption(kWh/24h) |
6.09 |
11.17 |
13.09 |
12.82 |
16.02 |
23.44 |
19.98 |
Noise(db) |
50 |
52 |
52 |
50 |
53 |
50 |
55 |
Ambient temperature(°C) |
10~32°C |
10~32°C |
10~32°C |
10~32°C |
10~32°C |
10~32°C |
10~32°C |
Temperature range(°C) |
-40~-86°C |
-40~-86°C |
-40~-86°C |
-40~-86°C |
-40~-86°C |
-40~-86°C |
-40~-86°C |
Cooling system |
Compressor brand/QTY |
SECOP/1 |
CUBIGEL/1 |
SECOP/1 |
SECOP/1 |
SECOP/2 |
SECOP/2 |
SECOP/2 |
Sensor |
PTC |
PTC |
PTC |
PTC |
PTC |
PTC |
PTC |
Temperature controller |
Microprocessor |
Microprocessor |
Microprocessor |
Microprocessor |
Microprocessor |
Microprocessor |
Microprocessor |
Display |
Digital display |
Digital display |
Digital display |
Digital display |
Digital display |
Digital display |
Digital display |
Power |
Voltage/frequency(V/Hz) |
220/50Hz |
220/50Hz |
220/50Hz |
220/50Hz |
220/50Hz |
220/50Hz |
220/50Hz |
Power(W) |
442W |
660W |
810W |
890W |
1500W |
1400W |
1700W |
Current(A) |
3.18A |
3.14A |
5.13A |
5.34A |
10.35A |
10.37A |
10.75A |
Material |
Inside material |
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
Stainless steel |
Outside material |
Color sprayed steel |
Color sprayed steel |
Color sprayed steel |
Color sprayed steel |
Color sprayed steel |
Color sprayed steel |
Color sprayed steel |
Insulation |
PURF |
PURF |
PURF |
PURF |
PURF |
PURF |
PURF |
Size |
Capacity(L/cu.ft) |
58L/2 |
188/6.63 |
340/12 |
408/14.40 |
588/20.76 |
728/25.7 |
838/29.59 |
NT./GT.(kg) |
115/155 |
174/224 |
222/283.5 |
234/291 |
290/360 |
374/394 |
344/430 |
Exterior size(W*D*H)(mm) |
635*757*1212 |
850*930*1595 |
875*980*1900 |
890*930*1945 |
880*1090*1995 |
1229*1012*1994.5 |
1175*1075*1990 |
Interior size(W*D*H)(mm) |
330*453*410 |
465*465*830 |
488*607*1140 |
606*575*1180 |
606*738*1310 |
963*571*1350 |
894*718*1310 |
Frozen Racks |
Racks |
2(6X2) |
9(4X3) |
12(4X4) |
16(5X4,4X4) |
16(5X5) |
24(5*4/6*4) |
24(5X5) |
Boxes (2 Inches) |
24 |
108 |
192 |
288 |
400 |
504 |
600 |
Samples(2ml) |
2400 |
10800 |
19200 |
28800 |
40000 |
50400 |
60000 |
Alarm |
High/low temperature |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Power failure |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Abnormal voltage |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Sensor error |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Filter screen check |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Thermostat failure |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Low battery |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Condenser clean |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
High ambient temperature |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Door ajar |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Power failure backup system(alarm) |
72h |
72h |
72h |
72h |
72h |
72h |
72h |
Accessories |
Castor |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Inside door |
1 |
3 |
2 |
2 |
2 |
2 |
2 |
Test hole QTY/diameter |
1/25MM |
1/25MM |
1/25MM |
1/25MM |
1/25MM |
1/25MM |
1/25MM |
USB port |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Chart recorder |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
Data logger |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Remote alarm port |
Y |
Y |
Y |
Y |
Y |
Y |
Y |
Optional |
CO2 back up system |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
LN2 back up system |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
Other |
Certification |
ISO.CE |
ISO.CE |
ISO.CE |
ISO.CE |
ISO.CE |
ISO.CE |
ISO.CE |