Model | Single temperature zone | Double temperature zone | ||||||
CVD-LTF16P50 | CVD-LTF16P60 | CVD-LTF16P80 | CVD-LTF16P100 | CVD-LTF16P60S | CVD-LTF16P80S | CVD-LTF16P100S | ||
CVD-LTF16T50 | CVD-LTF16T60 | CVD-LTF16T80 | CVD-LTF16T100 | CVD-LTF16P60S | CVD-LTF16T80S | CVD-LTF16T100S | ||
Performance | Operating temperature range | 300~1600℃ | ||||||
Temperature resolution | 1℃ | |||||||
Temperature control | ± 1℃ | |||||||
Heating rate | 0~20℃/min | |||||||
Heating zone length | 260mm | 600mm | ||||||
Length of constant temperature zone | 120mm | 300mm | ||||||
degree of vacuum | -0.1MPa | |||||||
Empty furnace heating time | <15min | |||||||
Composition | Exterior | Cold-rolled steel sheet with chemical-resistant coating on the surface | ||||||
Furnace body | Polycrystalline Mullite Fiber | |||||||
Furnace size | 440*390*330 | 780*390*330 | ||||||
Furnace tube | Corundum Tube | |||||||
Furnace tube size | φ50*1000 | φ60*1000 | φ80*1000 | φ100*1000 | φ60*1200 | φ80*1200 | φ100*1200 | |
Heater | Silicon molybdenum rod | |||||||
Heating power | 4KW | 4KW | 10KW | 10KW | ||||
Thermal insulation layer | Double-layer forced air diversion | |||||||
Controller | Controller | P: Imported program temperature control digital display; T: 7-inch color touch screen program temperature control | ||||||
Control method | Use microcomputer PID control / S-type dual temperature zone separate temperature control | |||||||
How to set | P: Touch the five buttons for action, digital display setting; T: Touch the finger to set | |||||||
Display method | P: Double-line LED digital display; T: Color LCD display | |||||||
Timing | 0~999.9 hours | |||||||
Run function | Fixed value operation, program operation | |||||||
Program mode | P: Program running, 4 curves, 40 steps in total; T: 50 steps can call the stored program | |||||||
Sensor | Type S thermocouple | |||||||
Auxiliary function | P: Correction function; T: Correction function, real-time curve recording, U disk data export | |||||||
Safety equipment | Overcurrent leakage protection switch | Overcurrent protection switch | ||||||
Mass Flow Control System | Number of air paths | 3 channels (the number of air channels can be selected according to specific needs) | ||||||
Flow range | 0-0500sccm (standard ml/min, optional) nitrogen standard | |||||||
Precision | ±1%F.S | |||||||
Response time | ≤4s | |||||||
Operating temperature (flow meter) | 5-45℃ | |||||||
Work pressure | Inlet pressure 0.05-0.3MPa (gauge pressure) | |||||||
System connection | Adopt KF quick connection bellows, high vacuum manual flapper valve and digital display vacuum measuring instrument | |||||||
Medium vacuum control system | System vacuum range | 10-100Pa | ||||||
Vacuum pump | The theoretical ultimate vacuum degree of the two-stage mechanical pump is 3x10-1Pa, the pumping rate is 4L/s, the air outlet is equipped with an oil filter, the rated voltage is 200V, and the power is 0.55Kw | |||||||
CVD system configuration | 1600 degree vacuum tube furnace (optional single temperature zone, double temperature zone) Multi-channel mass flow control system Vacuum system | |||||||