Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker

Product Details
Customization: Available
Application: Industry
Customized: Customized
Still deciding? Get samples of US$ 2000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Other, Group Corporation
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
501~1000 square meters
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
  • Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
Find Similar Products

Basic Info.

Model NO.
LH-300D, 311D, 322D
Certification
CE, ISO, RoHS
Structure
Desktop
Material
Stainless Steel
Type
Incubator
Display Method
LCD (Large Screen LCD Dual Display)
Cyclic Mode
Forced Convection
Oscillation Mode
Rotary Oscillation
Temperature Range
Room Temperature+5c-60c, 4c-60c
Temperature Accuracy
+/0.1c
Temperature Uniformity
+/-1c
Rotation Frequency
30-300rpm
Rotation Accuracy
+/-1rpm
Timing Range
0-999.59h/ Sustainable
Annex
Lighting, Ultraviolet Light
Pendulum
25mm
Control Method
Microcomputer Environment Scanning Micro Processin
Drive Mode
Single-Axis Balancing Device (Chinese Patent)
Transport Package
Standard Shipping Packaging
Specification
1350*645*1620mm
Trademark
LABOAO
Origin
China
HS Code
847982009
Production Capacity
3000

Product Description

Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker

Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker


Microbial aerobic bacteria used in antibiotics, oxygen (air) must be continuously supplied during the cultivation process. Otherwise the microorganisms cannot grow better and synthesize antibiotics. Therefore, when using a shaker to culture microorganisms, the eccentricity and rotation speed of the shaker are one of the important factors affecting the growth of microorganisms and the synthesis of antibiotics. So far, the advent of the shaker has created better experimental conditions for the research and application of biopharmaceuticals in China.

 

Feature
 
 

1.       Eight sections of self-programming, each program can set different speed and time to realize the programming operation of speed and appointment time.

2.       Automatic operation, automatic stop, timed operation, clock display, call recovery, parameter memory.

3.       Watchdog timers, independent overspeed sound/light alarms, independent leakage, and over-current protection devices do not affect other equipment.

4.       The PID microprocessor control/monitoring system provides simple button operation and easy programming of time and speed.

5.       The original single-axis drive mechanism in China is quiet and durable.

6.       The most advanced finishing technology in the country ensures the stability and reliability of mechanical operation.

7.       The key parts of the movement are made of expensive chrome alloy material, high quality cast iron and original imported bearings.

8.       The last set speed is automatically memorized and slowly accelerated to the last running speed after power on.

9.       The unique slow start line prevents sudden starts and splashes, ensuring safe reagents.

10.    Unique motor overheating, temperature out of control automatic power off protection device.

11.    Unique high-precision frequency control system with frequency accuracy of ±1rpm.

12.    The most advanced large torque motor, maintenance-free, and guaranteed continuous operation.

13.    The electrostatic color spray box is beautiful and rustproof, and has an aesthetic design concept.

14.    The cabinet is made of high quality, high strength cold rolled steel, medium, channel, angle and cast iron.



Security
  1. Leakage current and overcurrent protection systems ensure operator safety.
  2. Over-temperature, over-speed sound and light alarm emergency control system to ensure sample safety
Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
Lab Shaker Small Bottle Shaker Orbital Shaking Incubator ShakerLab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
Specification

 
Product number LH-300D LH-311D LH-322D
control method P.I.D microcomputer environment scanning micro-processing chip control
Display method LCD liquid crystal display
Programming mode Eight-segment user-programming
safety protection Self-running, automatic stop, timed operation, call recovery, parameter memory
Accessory function Watchdog timer, independent overspeed sound/light alarm, independent leakage, leakage overcurrent protection device
Cyclic mode Natural convection
Timing range 0-999.59 hours / sustainable
Oscillation mode Rotary oscillation
Drive mode Single-axis balanced drive (Chinese patent)
Environmental requirements User-specific thermostat or environment
index Rotation range 30-300rpm
 
Rotation accuracy ±1rpm
Pendulum amplitude φ50mm
Standard sizes Rocker size 680*500 840*620 1108*740
Number of rocking plates one
net weight 60kg 200kg 250kg
Product Size 680*615*300 900*650*480 1210*775*480
power 70W 150W 280W
Motor 60W inverter motor 120W inverter motor 280W inverter motor
power supply AC 200-240V 50-60HZ
Outer box High quality and high strength cold rolled steel plate, medium plate, channel steel, angle steel, cast iron

 
Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker
Lab Shaker Small Bottle Shaker Orbital Shaking Incubator Shaker


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More