Customization: | Available |
---|---|
Magnification: | >1000X |
Type: | Biological |
Still deciding? Get samples of US$ 550/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A biological microscope is a precision optical instrument used to observe biological sections, biological cells, bacteria, living tissue culture, and fluid sedimentation. It can also observe other transparent or translucent objects as well as objects such as powder and fine particles. The biological microscope is used for the observation of microorganisms, cells, bacteria, tissue culture, suspensions, sediments, etc. in medical and health units, universities, and research institutes. It can continuously observe the process of cell and bacteria reproduction and division in culture fluid Wait. It is widely used in cytology, parasitology, oncology, immunology, genetic engineering, industrial microbiology, and botany. Its optical technical parameters include: numerical aperture, resolution, magnification, focal depth, field of view width, poor coverage, working distance, etc. These parameters are not all as high as possible. They are both interrelated and restricted. In practical applications, the relationship between the parameters should be coordinated according to the purpose of the microscopy and the actual situation on the basis of ensuring the resolution.
Microscope with 3WLED Illumination Systems (LBM-2 Series)
Feature
1. Mirror holder. Located at the bottom of the microscope to support the full lens.
2. Mirror arm. Located behind the lens barrel, it is usually arched to support the lens barrel and hold the part when moving the microscope.
3. The lens barrel. It is located above the microscope, the eyepiece is connected to the upper part, and the objective lens converter is connected to the lower part.
4. Objective lens converter. The turntable located below the lens barrel usually has 3 to 4 circular holes, which can be equipped with objective lenses of different magnifications, allowing each objective lens to form a magnifying system through the lens barrel and the eyepiece.
5. Mobile station. Also known as stage, workbench, or stage, used to place specimens. There are two metal clamps on the moving stage called specimen clamps, which are used to fix slide specimens. Some stages are equipped with sliders for moving specimens, and some stages can be moved by themselves.
6. Focusing device. In order to obtain a clear image, the distance between the objective lens and the specimen must be adjusted so that the focus of the objective lens is aligned with the specimen. This operation is called focusing. Focusing is achieved with the coarse and fine focus knobs.
Specification
Microscope with Low position operation, convenient for long-term using (LBM-3 Series)
Feature
1. High resolution and perfect definition from infinity correct optical system
2. 100X water objective instead of 100X oil objective, more be convenient for using
Perfect Appearance Design
1. Drop-style integrated appearance design, looks elegant
Perfect Ergonomics Design
1. Low position operation, convenient for long-term using
2. New wound device for cable, easy to move and keeping
3. The changing of objectives can be watched by back side through the back watching window
Specification
Inverted trinocular microscope Apply to observation and cultivation for cell tissue(LBIM-400 series)
Feature
1 New research and new development
2 Apply to observation and cultivation for cell tissue
3 Wide field eyepiece, view field up to Φ23mm,more comfortable for observation
4 Long working distance condenser N.A. 0.30,Working distance:72mm
5 Working distance: 195mm (without condenser),available for extra high culture dish
6 Large size stage, convenient for research. Size:240mm(X)× 210(Y)mm
7 Mechanical stage available for 96 holes plate. Moving range:128mm(X)× 80(Y)mm
8 Large diameter quintuple nosepiece can be installed more objectives, more convenient for using.
9 Light distribution (both): 100 : 0 (100% for eyepiece);80 : 20 (80% for trinocular head and 20% for eyepiece)
SpecificationBiological inverted microscope for life science research(LBIM-500)
Feature
1 Brand-new development for life science research
2 Both light ports for digital camera and SLR photography, available for observing with digital camera and SLR photography at the same time
3 IOS Infinity optical system, perfect for cell observation and culture
4 Automatic infrared induction for power on-off.
5 Special light port for SLR digital camera, 7°inclined up to be more
6 Power off upon user leaving 10 minutes, and power on upon user approaching. convenient to observe the image of the SLR camera.
7 12V/50W Kohler illumination makes the field more even and brighter.
8 4-hole rotating disc phase contrast condenser for standard to change bright field and phase contrast fast
Specification
Trinocular microscope with Interpupilary distance:48mm-76mm(LBM-6000 series)
1 Wide field eyepiece, view field up to Φ22mm,more comfortable for observation
2 Trinocular observing tube with dual transform
3 Light distribution (both): 100 : 0(100% for eyepiece)80 : 20(80% for trinocular head and 20% for eyepiece)
4 Integrated stage is safer than traditional stage
5 Quintuple turret phase contrast unit with 10X/20X/40X/100X infinity plan phase contrast objective for phase contrast and bright field observation.
6 N.A.0.9/0.13 Swing-out Condenser
7 Dark field condenser(dry)available to 4X-40X Objective
8 Dark field condenser (wet) available to 100X Objective
Microscope with Excellent OTICS infinity optical system(LBM-S E series)
Feature
1 Excellent OTICS infinity optical system, outstanding resolution and definition.
2 Original integrated stand for excellent stability.
3 Unique aspheric illumination system, provide bright and comfortable lighting.
4 Various colorful matching looking can provide lively environment and happy mood.
5 Various accessories for upgrading.
6 Back handle and observing hole convenient for carry and operation.
7 Alternative color for main body.
Specification