Hospital Large Horizontal Constant Temperature Lab Shaker Medical Equipment
The constant temperature shaker has a stainless-steel universal clamp, digital display temperature control, stepless speed regulation and good thermal cycle function. It is a multi-purpose biochemical device, which is a plant, biology, microbiology, genetics, virus, environmental protection, medicine and other scientific research. education and production departments for precision culture preparation of indispensable laboratory equipment
Feature
- The original technology of the original single-axis drive balance device (patent type: a single-axis drive swing balance mechanism; patent number: ZL 2015 2 0624431.5), to ensure minimum energy consumption and noise.
- The oscillation frequency can be extended over a wide range to 50-300 rpm.
- Intelligent sound and light alarm environment scanning microprocessor controller.
- The LCD large-screen backlit LCD display double displays each set parameter and measured parameter.
- 211/B/C/D/F type safety and fluorine-free refrigeration system that meets international environmental protection requirements.
- Elastic cylinder support is used to ensure smooth opening and closing of the cover.
- Run the parameter memory function to avoid cumbersome operations.
- AC induction long life motor design, wide speed regulation, constant torque, constant speed, no carbon brush, maintenance free.
- Over-temperature sound and light alarm function, motor overheating, temperature out of control, abnormal over-temperature instrument automatically cut off their respective power supply.
- With power-off recovery function, after the external power supply suddenly loses power and calls again, the device can automatically resume operation according to the original setting program.
- The line that controls the acceleration ensures that the shaker is slowly started and smoothly accelerated to ensure the safety of the experimental samples.
- The streamlined luxury machine model with rich aesthetic design concept, electrostatic spray box, large screen tempered glass window.
- The floor-standing shaker has a large capacity and full-featured, and can accommodate 5L culture bottles to meet your experimental needs.
- Available in both temperature and low temperature ranges.
- The new streamlined luxury machine shape, color electrostatic spray box.
- The transparent viewing window and built-in lighting design make it easy to view samples at any time.
- Observe the temperature, oscillation speed and time at the same time.
- Equipped with casters for easy placement and movement anywhere.
- A variety of accessories: UV germicidal lamps, humidity detection or control, intake pipe, lighting system, etc., to optimize your training program.
- LH-111B/211B is a standard type that can hold up to 2000ML flasks.
- LH-111C/211C is a heightening type that can hold up to 5000ML flasks.
Application range
1.Cell culture
2.Solubility test
3.Extraction experiment
4.Diagnostic test
5.Mixing samples
6.Bacterial suspension preparation
7.Dyeing and bleaching
8.Elution process
9.Hybrid experiment
10. Protein
Security
- Leakage current and overcurrent protection systems ensure operator safety.
- Over-temperature, over-speed sound and light alarm emergency control system to ensure sample safety
Specification
Product number |
LH-111B |
LH-211B |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
LCD (Large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Rotary oscillation |
Drive mode |
Single-axis balancing device (Chinese patent) |
Environmental requirements |
Temperature 5-25 ° C, humidity 20% -90% |
Temperature control range |
Room temperature +5ºC-60ºC |
4-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
Performance |
Frequency Range |
30-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
Φ25mm |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
Heater |
800W |
800W |
Timing range |
0-999.59h/ Sustainable |
Standard sizes |
Rocker size |
920*500(mm) |
920*500(mm) |
Number of rocking plates |
one |
Gross weight |
159kg |
185kg |
Inner cavity size |
970*550*350 (mm) |
970*550*350 (mm) |
Dimensions |
1250*740*840 (mm) |
1250*740*840 (mm) |
Package dimensions |
1340*860*1070 (mm) |
1340*860*1070(mm) |
power |
960W |
1120W |
power supply |
AC 200-240V 50-60HZ |
Materia |
Motor |
120W inverter motor |
Inner cavity material |
High quality imported stainless steel mirror panel |
box Materia |
High quality and high strength castings, channel steel, angle steel, cold rolled steel plate |
Product number |
LH-111C |
LH-211C |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
LCD (Large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Rotary oscillation |
Drive mode |
Single-axis balancing device (Chinese patent) |
Environmental requirements |
Temperature 5-25 ° C, humidity 20% -90% |
Temperature control range |
Room temperature +5ºC-60ºC |
4-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
Performance |
Frequency Range |
30-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
Φ25mm |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
Heater |
800W |
800W |
Timing range |
0-999.59h/ Sustainable |
Standard sizes |
Rocker size |
920*500(mm) |
920*500(mm) |
Number of rocking plates |
one |
Gross weight |
160kg |
185kg |
Inner cavity size |
970*550*460 (mm) |
970*550*460 (mm) |
Dimensions |
1250*740*980 (mm) |
1250*740*980 (mm) |
Package dimensions |
1340*860*1220 (mm) |
1340*860*1220(mm) |
power |
960W |
1120W |
power supply |
AC 200-240V 50-60HZ |
Materia |
Motor |
120W inverter motor |
Inner cavity material |
High quality imported stainless steel mirror panel |
box Materia |
High quality and high strength castings, channel steel, angle steel, cold rolled steel plate |
Product number |
LH-111D |
LH-211D |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
LCD (Large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Rotary oscillation |
Drive mode |
Single-axis balancing device (Chinese patent) |
Environmental requirements |
Temperature 5-25 ° C, humidity 20% -90% |
Temperature control range |
Room temperature +5ºC-60ºC |
4-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
Performance |
Frequency Range |
30-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
Φ50mm |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
Heater |
800W |
800W |
Timing range |
0-999.59h/ Sustainable |
Standard sizes |
Rocker size |
920*500(mm) |
920*500(mm) |
Number of rocking plates |
one |
Gross weight |
159kg |
180kg |
Inner cavity size |
970*550*350 (mm) |
970*550*350 (mm) |
Dimensions |
1250*740*840 (mm) |
1250*740*840 (mm) |
Package dimensions |
1340*860*1070 (mm) |
1340*860*1070(mm) |
power |
960W |
1120W |
power supply |
AC 200-240V 50-60HZ |
Materia |
Motor |
120W inverter motor |
Inner cavity material |
High quality imported stainless steel mirror panel |
box Materia |
High quality and high strength castings, channel steel, angle steel, cold rolled steel plate |
Product number |
LH-111F |
LH-211F |
control method |
P.I.D(Microcomputer environment scanning micro processing chip) |
Display method |
LCD (Large screen LCD dual display) |
Cyclic mode |
Forced convection |
Oscillation mode |
Reciprocating |
Drive mode |
Single-axis balancing device (Chinese patent) |
Environmental requirements |
Temperature 5-25 ° C, humidity 20% -90% |
Temperature control range |
Room temperature +5ºC-60ºC |
4-60ºC |
Temperature accuracy |
±0.1ºC |
Temperature uniformity |
±1ºC |
Performance |
Frequency Range |
30-300rpm |
Rotation accuracy |
±1rpm |
Pendulum amplitude |
Φ25mm |
security function |
Upper and lower temperature deviation alarm; upper- and lower-line speed deviation alarm, independent over-temperature protector; open door stop protection; leakage protection, chiller overload protection. |
Accessory function |
Speed storage, call recovery, parameter memory, temperature speed correction, clock display, room temperature / measured temperature double display. |
Programming function |
Repeat, step, eight-segment curve programming settings. |
The refrigerant |
- |
CFC-Free (134A) fluorine-free safety refrigeration system |
Cooler |
- |
200W |
Heater |
800W |
800W |
Timing range |
0-999.59h/ Sustainable |
Standard sizes |
Rocker size |
920*500(mm) |
920*500(mm) |
Number of rocking plates |
one |
Gross weight |
150kg |
175kg |
Inner cavity size |
970*550*350 (mm) |
970*550*350 (mm) |
Dimensions |
1250*740*840 (mm) |
1250*740*840 (mm) |
Package dimensions |
1340*860*1070 (mm) |
1340*860*1070(mm) |
power |
960W |
1120W |
power supply |
AC 200-240V 50-60HZ |
Materia |
Motor |
120W inverter motor |
Inner cavity material |
High quality imported stainless steel mirror panel |
box Materia |
High quality and high strength castings, channel steel, angle steel, cold rolled steel plate |