Customization: | Available |
---|---|
Customized: | Non-Customized |
Structure: | Desktop |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description
Gentier 48E real-time PCR detection system is specially designed for workers in small and medium-sized laboratories, mobile laboratories, and on-site detection. With excellent performance and portability, make your testing more convenient, accurate and efficient.
Feature
Excellent performance:
Detection flux: 48-well 4-color fluorescence detection, each tube can detect 4 items at the same time, which greatly improves the experimental efficiency and avoids the inconvenience caused by repeated sample detection.
Temperature control: The maximum heating rate is up to 8 ° C / s, and the maximum cooling rate is up to 6.1 ° C / s. It only takes 30min to complete a standard PCR amplification procedure, which can realize your rapid detection; the temperature accuracy is controlled within ± 0.1 ° C To ensure good repeatability and accuracy.
Fluorescence scan: It takes only 2s to complete all 48-well 4-color fluorescence scans. For users who need to use the high-resolution melting curve (HRM) function, it can significantly reduce the overall test time and greatly improve work efficiency.
Convenient operation:
Built-in 7-inch full-color touch screen, independent control system and USB data export function, without the need to connect to a computer, the entire experiment can be completed in a single machine operation.
Full Chinese system interface and wizard-based parameter setting. After simple training, you can fully grasp the standard use of the instrument and quickly have the ability to independently operate experiments.
Standard network interface, through the setting of network parameters, can realize remote operation, experiment monitoring and data transmission in LAN.
Powerful data processing:
Multi-use in one machine: In addition to conventional analysis functions such as relative quantification, absolute quantification, HRM, and SNP, it is more compatible with a variety of isothermal amplification technologies for fluorescence analysis and truly realizes one machine for multiple uses.
Complex data analysis: In addition to the instrument operation software, it is also equipped with a set of independent data management software to achieve centralized management, statistics, and analysis of users' massive experimental data, reducing errors caused by complex analysis of the original data manually.
Universal report function: The built-in universal report function can adjust and customize the experimental report format according to the needs of different users, and establish its own unique experimental report style.
Excellent environmental adaptability:
Small size, light weight, easy to carry, can be moved to the required place or equipped to a mobile laboratory for on-site testing according to needs.
Using a fixed fluorescence detection unit, no need to perform any calibration work after moving, it can be started directly.
Application areas:
Rapid food safety testing
Public health on-site testing
Small and Medium-sized Scientific Research Labs
Clinical Immediate Test (POCT)
Specification
Detection flux |
48 0.2ml transparent 48-well plate without skirt, octaplex tube, single tube, etc. |
Applicable dyes / probes |
Channel 1: FAM, SYBR Green I, etc. Channel 2: VIC, HEX, TET, JOE, etc. Channel 3: ROX, Texas Red, etc. Channel 4: Cy5, etc. |
reaction system |
5μl~100μl |
Power Specifications |
AC 220V(±10%),50Hz,600VA |
Communication Interface |
Ethernet (RJ45), USB |
weight |
11 Kg |
Dimensions |
260*400*260mm(W*L*H) |
Temperature Control System |
|
Temperature control technology |
Semiconductor refrigeration chip heating and cooling technology |
Temperature control range |
0.0ºC~100.0ºC |
Temperature accuracy |
≤ 0.1ºC |
Module temperature control accuracy |
≤ 0.1ºC |
Temperature uniformity |
±0.1ºC |
Heating rate |
8ºC/s |
Average heating rate |
6.1ºC/s |
Cooling rate |
6.1ºC/s |
Average cooling rate |
4.0ºC/s |
Temperature gradient |
support |
Gradient range |
35ºC~100ºC |
Gradient span |
1ºC~40ºC |
Temperature control program |
Supports standard PCR, gradient PCR, landing PCR, long fragment PCR, etc. |
Temperature range of hot lid |
40ºC~110ºC |
Optical system |
|
Excitation light source |
Highlight maintenance-free LED |
Fluorescence detection device |
Photodiode |
Fluorescence scan time |
48-hole 4-color detection in 2s |
Excitation wavelength |
Channel 1: 470nm Channel 2: 523nm Channel 3: 571nm Channel 4: 630nm |
Detection wavelength |
Channel 1: 525nm Channel 2: 564nm Channel 3: 612nm Channel 4: 670nm |
Fluorescence linear |
≥0.990 |
Sample repeatability |
Ct value CV% ≤ 0.5% |
Sample linear |
/r/≥0.999 |
Software parameters |
|
display |
7-inch full-color touch display for stand-alone operation |
Software functions |
Supports absolute quantification, relative quantification, isothermal amplification, genotyping, endpoint fluorescence analysis, etc. |
language support |
Support Chinese / English bilingual switching |
data storage |
Can store ≥1000 experiment setup files / experiment data files |
remote control |
Can realize one main control computer to control 10 instruments |
Power failure protection |
Instantaneous power failure protection, continue to run unfinished experiments after the instrument restarts |
Data import and export |
Support U disk import and export of experimental data |